Universal control module for motorized devices
Transkript
Universal control module for motorized devices
Universal control module for motorized devices Ref: MOD-0105-N The MOD-0105-N is a universal module for motorized devices, blinds, awnings, curtains, doors, etc.. Allows, with vivimat® BUS , the local or remote control of a motorized devices, ensuring a reliable use of the motor in both cases. One of its most common uses is to combine the management of various motorized devices, and to control them centrally in a safe way, while the direct access from the individual push buttons of each device is still operational. Technical characteristics Number of motorized devices 1 Power supply 230VAC 50Hz Consumption <0,5W Output type 2 Relies NO de 5A/250VAC connected to phase Maximum engine power 500W Overcurrent and overvoltage protection Via electronic fuses and varistors Temperature range -10ºC / 40ºC Compatible with vivimat® III Communication with the vivimat® system LED status indication Through the vivimat® BUS ID configuration in the BUS via switch Panel installation DIN rail mounting Requires adaptation kit ADP-0010 (NOT INCLUDED) Universal control module for motorized devices Dimensions - + 42 mm 70 mm 70 mm 44 mm 25 mm 25 mm 70 mm 35 mm * MOD-0105 + adaptation part ADP-0010 for DIN rail. (NOT INCLUDED) Connections vivimat® BUS Switches Manual push down buttons + Manual push up buttons - Remote push down buttons + - Remote push up buttons Neutral motor N - Output Output motor down Output motor up Phase F N TT-230 Vac - Wiring: All wires of 0,22mm2 Neuter Earthing Universal control module for motorized devices Configuration Via the switches the MOD-0105-N can define its module address in the vivimat® BUS . vivimat® III can have up to 50 motorized devices control modules. Select the address of each module as indicated in the configuration made with vivimat® Project. The addresses of the modules are consecutively assigned by vivimat® Project (There must not be 2 modules of the same type with the same address). ADDRESS 1 ADDRESS 2 ON ADDRESS 3 ON 1 2 3 4 5 6 1 ADDRESS 10 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 3 4 5 6 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 3 4 5 1 2 3 4 5 2 3 4 5 2 3 4 5 6 2 3 4 5 2 3 4 5 1 2 3 4 5 2 3 4 5 1 6 1 2 3 4 5 6 2 3 4 5 6 2 3 4 5 2 3 4 5 1 6 2 3 4 5 4 5 6 2 3 4 5 2 3 4 5 6 1 2 3 4 5 2 3 4 5 6 ADDRESS 49 3 4 5 6 2 3 4 5 6 2 3 4 5 1 2 3 4 5 6 2 3 4 5 1 5 6 2 3 4 5 6 2 3 4 5 1 2 3 4 5 6 2 3 4 5 2 3 4 5 6 1 4 5 6 2 3 4 5 6 2 3 4 5 6 ADDRESS 36 ON 1 2 3 4 5 6 1 ADDRESS 44 6 3 ADDRESS 27 2 3 4 5 6 ADDRESS 45 ON 1 1 ADDRESS 35 6 2 ADDRESS 18 ON 1 1 ON ADDRESS 43 6 4 ADDRESS 26 ON 1 3 ON ADDRESS 34 6 2 ADDRESS 17 ON 1 1 ON ADDRESS 42 6 5 ADDRESS 25 ON 2 1 ADDRESS 33 ADDRESS 41 1 4 ON 1 6 3 ON ADDRESS 24 6 2 ON ADDRESS 16 ON 1 1 ON ADDRESS 32 6 3 ON 1 6 2 ADDRESS 9 ON ADDRESS 15 ON 1 1 ON ADDRESS 40 6 5 ADDRESS 23 ON 1 2 3 4 5 6 1 2 3 4 5 6 ADDRESS 50 ON 1 4 ON 1 6 3 ADDRESS 8 ON ADDRESS 14 ADDRESS 31 6 2 ON ADDRESS 48 6 1 ADDRESS 22 ON 1 6 ON ADDRESS 47 6 5 ON ADDRESS 39 ON 4 ON 1 6 3 ADDRESS 7 ON ADDRESS 13 ON ADDRESS 46 ON 1 1 6 2 ON ADDRESS 38 6 1 ADDRESS 30 ON 2 6 ON ADDRESS 37 ON 1 1 ADDRESS 29 6 5 ADDRESS 21 ON 1 4 ON ADDRESS 28 ON 3 ON ADDRESS 20 ON 2 2 ON ADDRESS 19 ON 1 1 ADDRESS 6 ON ADDRESS 12 ON ADDRESS 5 ON ADDRESS 11 ON ADDRESS 4 ON ON 1 2 3 4 5 6 1 2 3 4 5 6 The modules MOD-0105-N belonging to a vivimat® III system must be registered in the configuration of the installation which is implemented by vivimat® Project, assigning an ID number to the module and specifying which motorized devices, the module is going to control. Universal control module for motorized devices Functioning LOCAL CONTROL : Local control is carried out by on or more buttons connected in parallel (see connections). -A short key press (less than 0,5 sec.) will move totally up or down (motorized device). depending on the push button you have press (up or down) - If the device is moving, a short pressing in the opposite direction will stop the device. - A long key press on the up or down buttons it will move up or down the device depending on the button you have pressed: In the panel you will just see the positions 0 - 20 - 40 - 60 - 80 - 100% REMOTE CONTROL: The control is carried out by the vivimat® home automation system BUS. It is possible to activate the following functions remotely: - Move up or down totally the motorized device. - Move up or down the motorized device to a certain position. 0 - 20 - 40 - 60 - 80 - 100% - Know the status of the motorized device: 0 - 20 - 40 - 60 - 80 - 100% - Configure the module. *SECURITY: The module prioritizes local orders to remote orders. If the module is executing an “up” or “down” order in the remote mode, the key press of any local key will stop the motorized devices. LED STATUS INDICATION: 1- Green blinking: Module operative . 2- Red blinking: Module in communication. 3- Red or NOT illuminated: Problems with the module. Universal control module for motorized devices Installation recommendations - Installation corresponding to a > 100 x 100mm box: The 100 x 100mm box is embedded in the wall of the housing. With 2 screws (NOT INCLUDED) we fix the MOD-0105-N to the box (1). 1 - DIN rail installation: For the DIN rail installation, you require the adaptation kit ADP-0010 (NOT INCLUDED), consisting of 2 pieces, which has to be inserted into the rear of the module (1). Once the pieces are inserted, we fit the module into the DIN rail (2). 1 Adaptation part x 2 3 FT-MOD-0105-N_11/01/10-ENG Product manufactured by: Dinitel 2000 S.A. - Avda. Otaola 20 20600 Eibar ( Guipúzcoa ) Spaint T. +34 902 111 220 / +34 943 820 458 F. +34 902 124 779 www.domotica-vivimat.com dinitel@dinitel.com