(N)GRDGÖU
Transkript
(N)GRDGÖU
KAUÇUK KABLOLAR (N)GRDGÖU YÜKSEK ESNEKL‹K Z‹NC‹R KABLOSU HIGH FLEXIBLE CHAIN CABLE 600/1000 V KABLO YAPISI * ‹LETKEN : Elektrolitik tavl›, s›n›f 5 bükülü kalayl› bak›r teller (iste¤e ba¤l› ç›plak iletken) * AYIRICI : ‹letkenlerin üzerine uygun bir ay›r›c› bant uygulanabilir * ‹ZOLASYON : 3GI3 Tipi elastomer bileflik * DAMAR RENKLER‹ : VDE 0293-308'e uygun * AYIRICI : Büküm üzerine uygun bir ay›r›c› bant uygulanabilir * ‹Ç KILIF : elastomer bileflik * DIfi KILIF : 5GM1b Tipi elastomer bileflik * RENK : Siyah (iste¤e ba¤l› olarak di¤er renkler) CABLE STRUCTURE * CONDUCTOR : Electrolytic annealed, class 5 stranded plain copper wires (plain conductor on request) * SEPARATOR : A suitable tape may be applied over the conductor * INSULATION : 3GI3 Type elastomer compound * CORE IDENTIFICATION : Acc. to VDE 0293-308 * SEPARATOR : A suitable tape may be applied over the laid-up * INNER SHEATH : elastomer compound * OUTER SHEATH : 5GM1b Type elastomer compound * COLOR : Black (other colors on request) TASARIM ÖZELL‹KLER‹ / DESIGN FEATURES KONSTRÜKS‹YON / CONSTRUCTION GENEL ÖZELL‹KLER / GENERAL REQUIREMENTS KULLANMA KILAVUZU / GUIDE TO USE ELEKTR‹KSEL DENEYLER / ELECTRICAL TESTS ELEKTR‹KSEL OLMAYAN DENEYLER / NON-ELECTRICAL TESTS YANGIN fiARTLARI ALTINDAK‹ DENEYLER / UNDER FIRE CONDITIONS TESTS : DIN VDE 0250-814 : DIN VDE 0250-1 : DIN VDE 0298-3 : DIN VDE 0472-501, 502, 503, 508 : DIN VDE 0472-401, 402, 602, 303, 615 : DIN VDE 0472-803, 804 ÇALIfiMA KARAKTER‹ST‹KLER‹ / OPERATING CHARACTERISTICS ‹LETKEN ‹fiLETME SICAKLI⁄I / CONDUCTOR OPERATING TEMPERATURE ‹LETKEN KISA DEVRE SICAKLI⁄I / CONDUCTOR SHORT-CIRCUIT TEMPERATURE ‹fiLETME SICAKLI⁄I / WORKING TEMPERATURE M‹N. BÜKME YARIÇAPI / MIN BENDING RADIUS AKIM TAfiIMA KAPAS‹TELER‹ / CURRENT CARRYING CAPACITIES ALEV‹ ‹LETMEZ / FLAME RETARDANT YA⁄A DAYANIKLI / OIL RESISTANT OZON DAYANIMI / OZONE RESISTANT SO⁄U⁄A DAYANIKLI / COLD RESISTANT YIRTILMAYA DAYANIKLI / TEAR RESISTANT MEKAN‹K GER‹LME DAYANIMI / MECHANICAL STRESSES RESISTANCE PATLAMA R‹SKL‹ ORTAMLAR / EX-PROOF UV DAYANIMLI / UV RESISTANT 110 : Max. 60ºC : Max. 200ºC : Sabit / Fixed : -40ºC … +60ºC Hareketli / Mobile : -25ºC … +60ºC : VDE 0298-3 Tab. 3 : VDE 0298-4 : VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 : HD/EN/IEC 60811-2-1, DIN VDE 0473-811-2-1 FR 076-064 I REV. 0 REV. TAR. 18.04.2011 I Sf. 1/2 RUBBER CABLES (N)GRDGÖU KULLANIM ALANI APPLICATION Yüksek mekanik etkenlere maruz kalan makinelerin hareketli parçalar›nda ve malzeme iflleme ünitelerindeki ba¤lant›y› sa¤lar. Sürekli k›vr›lma gerektiren operasyonlarda kullan›ma uygundur. Bireysel ekran yap›s› sayesinde elektromanyetik etkileri en aza indirir. These cables connect moving components of machines and material handling units under high mechanical stress as well as they are suitable for frequent bending operations.Thanks to its individually brading structure, it decreases the electromagnetic effects to minimum level ORTAM ENVIRONMENT Çeflitli kimyasallara, ya¤lara, asitlere ve ozona dayan›kl›d›r. Bina d›fl›nda, kuru, ›slak ve ya¤l› ortamlarda kullan›labilir. It is resistant to some chemicals, oil, acids and ozone. It can be used in open air, dry, damp and oily areas. GÜVENL‹K SAFETY Yanma esnas›nda alevi iletmez ve kendili¤inden sönerler. Maksimum sar›lma h›z› 120 m/dk d›r Çekme gerginli¤i 15N/mm2 yi aflmamal›d›r. Sar›lacak tamburun çap› kablo çap›n›n min. 20 kat› olmal›d›r. Do¤rudan toprak alt›na gömülmemelidir. It's flame retardant and self extinguishes during fire. Permitted running speed up 120m/min. Tensile stress must not exceed 15 N/mm2. Diameter of drum barrel should be min. 20 times of cable diameter. It shouldn’t be burried directly underground. ‹LETKEN SAYISI X KES‹T NO.CONDUCTORS X CROSS -SECTION (mm2) 1x35 1x50 1x70 1x95 1x120 1x150 1x185 3x35+3x16/3 3x50+3x25/3 3x70+3x35/3 4x4 4x6 4x10 4x16 4x25 4x35 4x50 5x4 5x6 5x10 5x16 5x25 18x1,5 24x1,5 30x1,5 36x1,5 12x2,5 18x2,5 24x2,5 30x2,5 36x2,5 FR 076-064 I REV. 0 REV. TAR. 18.04.2011 I Sf. 2/2 DIfi ÇAP OUTER DIAMETER Min.-Max. (mm) 12,3 15 16,5 18,9 20,8 22,9 24,8 27,7 32,5 39,1 13,9 15,9 18,2 22,9 26,9 30,1 35,7 15,7 17,5 20,8 24,6 29,5 16,2 18,7 22,1 23,3 24,6 2,5 21,5 24 26,4 - 13,9 16,6 18,5 20,9 22,8 24,9 27,8 30,7 35,5 42,1 15,5 17,9 20,2 24,9 29,9 33,1 38,7 17,7 19,5 22,8 27,6 32,5 18,2 20,7 24,1 25,3 27,6 17,9 23,5 27 29,4 BAKIR FAKTÖRÜ COPPER FACTOR (kg / km) 336 480 672 912 1152 1440 1776 1368 1896 2587 153.6 230.4 384 614.4 960 1344 1920 192 288 480 768 1200 172.8 259.2 345.6 432 518.4 580 432 576 720 864 KABLO A⁄IRLI⁄I CABLE WEIGHT (kg / km) 430 625 835 1070 1340 1650 2010 1800 2540 3570 350 475 680 1070 1600 2090 2970 450 575 865 1300 1940 440 615 805 930 1090 19.9 865 1110 1330 1550 111