M E M B R A C O N F I LT R A T I O N B . V. TECTRON (R) Singular C-shape anode cells for electrophoretic paints NO LEAKAGE REDUCED MAINTENANCE IMPROVED ANOLYTE FLOWPATTERN MORE SURFACE AREA LIGHT WEIGHT UNIVERSAL BRACKET MEMBRACON F I L T R A T I O N B .V . T ÜR K İ Y E G E NE L D İ S T R İ B ÜT Ö R Ü EMA İç ve Dış Ticaret Ltd.Şti. Şemsettin Günaltay Cad. Şenyuva Apt. No:121 Daire:4 Suadiye Kadıköy/Istanbul / Turkey Tel./Fax:+90 216 410 45 44 GSM: 0533 593 97 27 0541 593 9727 E-mail: info@ematicaret.com.tr www.ematicaret.com.tr The Electrode, Membrane and Guard are bonded together in a channel. The design eliminates leak points and creates a single, durable unit for easy start-ups Patents pending Properties. The Electrode is made from 316L stainless steel The Electrode has 0.429 m2/m of surface area with a 12.7 mm (1/2”) hole for electrical power connection. The membrane is anionselective for cathodic ecoat paints. Anolyte flows from a 1/2” connection to two internal inlets — one on each side of the electrode provide enhanced anolyte flow over the surface of the Electrode. The cell has a 1” NPT electrolyte return connection Current density of 32 - 54 amp/m² is typical at 200 - 400 volts. Recommended electrolyte flow rate is 8 lpm/m2 . Rim bracket is a universal design that allows for adjustment to fit over the typical bar welded to the rim of the E-coat tank. TYPE P4 TYPE P5 Electrode wall thickness 3,4 mm 4,2 mm Estimated dry weight 14,4 kg/m 17,2 kg/m Electrode area 0,429 m2/m 0,429 m2/m